Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
PLoS One ; 18(9): e0291938, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37738256

RESUMO

BACKGROUND: Several studies have shown an independent relationship between body mass index (BMI) and the incidence of atrial fibrillation (AF). However, little is known about the influence of BMI on AF recurrence after electrical cardioversion (ECV). METHODS: We selected 1121 patients who reverted to sinus rhythm after scheduled ECV and were included in three prospective Spanish registries of ECV in persistent AF. The patients were classified according to baseline BMI into three categories (normal weight, overweight, obesity). We assessed the influence of BMI on the rate of AF recurrence at 3 months. RESULTS: We identified 538 patients (48%) who had AF recurrence in the first 3 months after successful ECV. The patients who suffered AF recurrence had a higher BMI than those who remained in sinus rhythm (29.66±4.57 vs. 28.87±4.64 Kg/m2, respectively; p = 0.004). We observed a higher incidence of AF recurrence in the overweight and obese patients (BMI ≥25 kg/m2) than in those classified as normal weight (50.5% vs. 35.6%, respectively; p<0,001). BMI≥25 Kg/m2 was shown to be independently related to of AF recurrence in the multivariate analysis (OR = 1.75, 95% confidence interval = 1.20-2.58; p = 0.004). CONCLUSIONS: Increased BMI is independently related to AF recurrence after ECV. BMI should also be taken into account when making decisions about the indication for ECV in persistent AF.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Cardioversão Elétrica , Índice de Massa Corporal , Sobrepeso/complicações , Sobrepeso/terapia , Estudos Prospectivos , Obesidade/complicações , Obesidade/terapia
2.
Front Cardiovasc Med ; 10: 1110165, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37051067

RESUMO

Introduction: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). Methods: Observational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF. The duration of amplified P-wave (APW) was measured from a digitally recorded 12-lead electrocardiogram during the procedure. If patients were in AF, direct-current cardioversion was performed to allow APW measurement in sinus rhythm. An APW cut-off of 150 ms was used to identify patients with significant ACM. We assessed freedom from arrhythmia recurrence at long-term follow-up in patients with APW ≥ 150 ms vs. APW < 150 ms. Results: We included 295 patients (mean age 62.3 ± 10.6), of whom 193 (65.4%) suffered from persistent AF and the remaining 102 (34.6%) from long-standing persistent AF. One-hundred-forty-two patients (50.2%) experienced arrhythmia recurrence during a mean follow-up of 793 ± 604 days. Patients with APW ≥ 150 ms had a significantly higher recurrence rate post ablation compared to those with APW < 150 ms (57.0% vs. 41.6%; log-rank p < 0.001). On a multivariable Cox-regression analysis, APW≥150 ms was the only independent predictor of arrhythmia recurrence post ablation (HR 2.03 CI95% 1.28-3.21; p = 0.002). Conclusion: APW duration predicts arrhythmia recurrence post cryoballoon-PVI in persistent and long-standing persistent AF. An APW cut-off of 150 ms allows to identify patients with significant ACM who have worse outcomes post PVI. Analysis of APW represents an easy, non-invasive and highly reproducible diagnostic tool which allows to identify patients who are the most likely to benefit from PVI-only approach.

4.
JACC Basic Transl Sci ; 8(1): 1-15, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36777175

RESUMO

Analysis of the spatio-temporal distribution of calcium sparks showed a preferential increase in sparks near the sarcolemma in atrial myocytes from patients with atrial fibrillation (AF), linked to higher ryanodine receptor (RyR2) phosphorylation at s2808 and lower calsequestrin-2 levels. Mathematical modeling, incorporating modulation of RyR2 gating, showed that only the observed combinations of RyR2 phosphorylation and calsequestrin-2 levels can account for the spatio-temporal distribution of sparks in patients with and without AF. Furthermore, we demonstrate that preferential calcium release near the sarcolemma is key to a higher incidence and amplitude of afterdepolarizations in atrial myocytes from patients with AF.

6.
Europace ; 24(11): 1788-1799, 2022 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-35851611

RESUMO

AIMS: To determine the spectral dynamics of early spontaneous polymorphic ventricular tachycardia and ventricular fibrillation (PVT/VF) in humans. METHODS AND RESULTS: Fifty-eight self-terminated and 173 shock-terminated episodes of spontaneously initiated PVT/VF recorded by Medtronic implanted cardiac defibrillators (ICDs) in 87 patients with various cardiac pathologies were analyzed by short fast Fourier transform of shifting segments to determine the dynamics of dominant frequency (DF) and regularity index (RI). The progression in the intensity of DF and RI accumulations further quantified the time course of spectral characteristics of the episodes. Episodes of self-terminated PVT/VF lasted 8.6 s [95% confidence interval (CI): 8.1-9.1] and shock-terminated lasted 13.9 s (13.6-14.3) (P < 0.001). Recordings from patients with primarily electrical pathologies displayed higher DF and RI values than those from patients with primarily structural pathologies (P < 0.05) independently of ventricular function or antiarrhythmic drug therapy. Regardless of the underlying pathology, the average DF and RI intensities were lower in self-terminated than shock-terminated episodes [DF: 3.67 (4.04-4.58) vs. 4.32 (3.46-3.93) Hz, P < 0.001; RI: 0.53 (0.48-0.56) vs. 0.63 (0.60-0.65), P < 0.001]. In a multivariate analysis controlled by the type of pathology and clinical variables, regularity remained an independent predictor of self-termination [hazard ratio: 0.954 (0.928-0.980)]. Receiver operating characteristic (ROC) curve analysis of DF and RI intensities demonstrated increased predictability for self-termination in time with 95% CI above the 0.5 cut-off limit at about t = 8.6 s and t = 6.95 s, respectively. CONCLUSION: Consistent with the notion that fast organized sources maintain PVT/VF in humans, reduction of frequency and regularity correlates with early self-termination. Our findings might help generate ICD methods aiming to reduce inappropriate shock deliveries.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Arritmias Cardíacas , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia
7.
Clin Res Cardiol ; 111(9): 1018-1027, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34854991

RESUMO

AIMS: Despite advances in interventional treatment strategies, atrial fibrillation (AF) remains associated with significant morbidity and mortality. Fibrotic atrial myopathy (FAM) is a main factor for adverse outcomes of AF-ablation, but complex to diagnose using current methods. We aimed to derive a scoring system based entirely on easily available clinical parameters to predict FAM and ablation-success in everyday care. METHODS: In this multicenter, prospective study, a new risk stratification model termed AF-SCORE was derived in 220 patients undergoing high-density left-atrial(LA) voltage-mapping to quantify FAM. AF-SCORE was validated for FAM in an external mapping-validation cohort (n = 220) and for success following pulmonary vein isolation (PVI)-only (without adjunctive left- or right atrial ablations) in an external outcome-validation cohort (n = 518). RESULTS: FAM was rare in patients < 60 years (5.4%), but increased with ageing and affected 40.4% (59/146) of patients ≥ 60 years. Sex and AF-phenotype had additional predictive value in older patients and remained associated with FAM in multivariate models (odds ratio [OR] 6.194, p < 0.0001 for ≥ 60 years; OR 2.863, p < 0.0001 for female sex; OR 41.309, p < 0.0001 for AF-persistency). Additional clinical or diagnostic variables did not improve the model. AF-SCORE (+ 1 point for age ≥ 60 years and additional points for female sex [+ 1] and AF-persistency [+ 2]) showed good discrimination to detect FAM (c-statistic 0.792) and predicted arrhythmia-freedom following PVI (74.3%, 54.7% and 45.5% for AF-SCORE ≤ 2, 3 and 4, respectively, and hazard ratio [HR] 1.994 for AF-SCORE = 3 and HR 2.866 for AF-SCORE = 4, p < 0.001). CONCLUSIONS: Age, sex and AF-phenotype are the main determinants for the development of FAM. A low AF-SCORE ≤ 2 is found in paroxysmal AF-patients of any age and younger patients with persistent AF irrespective of sex, and associated with favorable outcomes of PVI-only. Freedom from arrhythmia remains unsatisfactory with AF-SCORE ≥ 3 as found in older patients, particularly females, with persistent AF, and future studies investigating adjunctive atrial ablations to PVI-only should focus on these groups of patients.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cardiomiopatias/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Fibrose , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
8.
Cardiovasc Res ; 118(4): 1033-1045, 2022 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-33788918

RESUMO

AIMS: Atrial fibrillation (AF) has been associated with intracellular calcium disturbances in human atrial myocytes, but little is known about the potential influence of sex and we here aimed to address this issue. METHODS AND RESULTS: Alterations in calcium regulatory mechanisms were assessed in human atrial myocytes from patients without AF or with long-standing persistent or permanent AF. Patch-clamp measurements revealed that L-type calcium current (ICa) density was significantly smaller in males with than without AF (-1.15 ± 0.37 vs. -2.06 ± 0.29 pA/pF) but not in females with AF (-1.88 ± 0.40 vs. -2.21 ± 0.0.30 pA/pF). In contrast, transient inward currents (ITi) were more frequent in females with than without AF (1.92 ± 0.36 vs. 1.10 ± 0.19 events/min) but not in males with AF. Moreover, confocal calcium imaging showed that females with AF had more calcium spark sites than those without AF (9.8 ± 1.8 vs. 2.2 ± 1.9 sites/µm2) and sparks were wider (3.0 ± 0.3 vs. 2.2 ± 0.3 µm) and lasted longer (79 ± 6 vs. 55 ± 8 ms), favouring their fusion into calcium waves that triggers ITIs and afterdepolarizations. This was linked to higher ryanodine receptor phosphorylation at s2808 in women with AF, and inhibition of adenosine A2A or beta-adrenergic receptors that modulate s2808 phosphorylation was able to reduce the higher incidence of ITI in women with AF. CONCLUSION: Perturbations of the calcium homoeostasis in AF is sex-dependent, concurring with increased spontaneous SR calcium release-induced electrical activity in women but not in men, and with diminished ICa density in men only.


Assuntos
Fibrilação Atrial , Cálcio , Cálcio/metabolismo , Sinalização do Cálcio/fisiologia , Feminino , Homeostase , Humanos , Masculino , Miócitos Cardíacos/metabolismo , Canal de Liberação de Cálcio do Receptor de Rianodina/metabolismo , Retículo Sarcoplasmático/metabolismo
9.
Clin Interv Aging ; 16: 739-745, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33953552

RESUMO

BACKGROUND: The European Heart Rhythm Association (EHRA) score is a proven and validated tool for assessing the symptoms of atrial fibrillation (AF). Little is known about the variables related to this score and how it changes after cardioversion. METHODS: We analyzed 744 patients undergoing elective cardioversion in whom AF-related symptoms were assessed at baseline and after 6 months of follow-up using the EHRA score. We assessed the association between the EHRA score and other clinical and echocardiographic variables at baseline and after 6 months of follow-up. RESULTS: At 6 months of follow-up, we observed a reduction in the EHRA score in 50% and worsening in 2.8% of patients who remained in sinus rhythm (SR) compared with 34.6% and 11.3%, respectively, of patients with AF episodes (p<0.0001). Patients who maintained SR at 6 months were less symptomatic than those with AF (EHRA score 1.13 ± 0.35 vs 1.42 ± 0.59; p<0.0001). The independent predictors for reduction in the EHRA score after cardioversion were NYHA ≥II at baseline and maintenance of SR (p<0.0001). CONCLUSION: The greatest improvement in AF-related symptoms was in patients who remained in SR at 6 months after cardioversion and in patients with worse NYHA functional class at baseline.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cardioversão Elétrica/métodos , Idoso , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Espanha
10.
J Clin Med ; 10(5)2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33802253

RESUMO

BACKGROUND: Antiarrhythmic drugs (AADs) are frequently initiated in patients with persistent atrial fibrillation (AF) prior to electrical cardioversion (ECV), achieving pharmacological cardioversion (PCV) in some cases. Little is known about the mode of cardioversion and the effect of the type of AAD used in the maintenance of sinus rhythm (SR). METHODS: From three national surveys of patients with persistent AF referred for ECV, we selected those who were pre-treated with AADs (amiodarone or group Ic AADs). We analyzed the effect of the type of cardioversion (pharmacological vs. electrical) and the AAD used in the maintenance of SR at three months. RESULTS: Among the 665 patients selected, 151 had a successful PCV prior to the planned ECV. In the remaining 514 patients, 460 had a successful ECV. A successful PCV was related to a higher rate of SR maintenance than a successful ECV (77.9% vs. 57.5%; p < 0.0001). After a successful PCV, the maintenance of SR was identical in those patients treated with amiodarone and those treated with group Ic AADs (77.4% vs. 77.5%; p = 0.99), whereas after a successful ECV, amiodarone was clearly superior to group Ic AADs (61.3% vs. 43.0%; p = 0.001). Considering patients with successful PCV and ECV together, PCV was an independent factor related to the maintenance of SR. CONCLUSIONS: In patients with persistent AF, successful PCV selects a subgroup with a high probability of maintenance of SR. With regard to drugs, amiodarone was superior to group Ic AADs in patients with ECV, whereas in PCV, no differences were observed.

11.
Rev. esp. cardiol. (Ed. impr.) ; 74(4): 296-302, Abr. 2021. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-232234

RESUMO

Introducción y objetivos El estudio ADVANCE III mostró una reducción de terapias del desfibrilador automático implantable (DAI) con el empleo de tiempos de detección de arritmia prolongados. Se describe la adopción y el impacto de dicha estrategia en la incidencia de terapias del DAI. Métodos Estudio observacional retrospectivo de pacientes con implante de DAI Medtronic (2005-2016) en un registro multicéntrico (UMBRELLA-NCT01561144). Se describe la evolución de la adopción de programación ADVANCE en relación con: publicación del estudio, implementación de una campaña de formación y publicación de un consenso de expertos. Se identificaron con regresión logística los predictores de la adopción. Se comparó la incidencia de terapias en pacientes con y sin programación ADVANCE estimando la razón de tasas de incidencia ajustada (RTIa) mediante regresión binomial negativa. Resultados Se incluyó a 3.528 pacientes. Se utilizó la estrategia ADVANCE en el 20% del total y el 44% al final del estudio. La adopción se incrementó tras publicarse el estudio ADVANCE, y en menor grado tras la campaña de formación y consenso de expertos. Predictores de la adopción: DAI con detección nominal 30/40 (ORa=4,4; IC95%, 3,5-5,4), implantador electrofisiólogo (ORa=1,7; IC95%, 1,4-2,2) y prevención secundaria (ORa=3,2; IC95%, 2,6-3,9). El implante de DAI bicameral (ORa=0,6; IC95%, 0,5-0,8) o tricameral (ORa=0,5; IC95%, 0,4-0,7) se asoció con menor adopción. La programación ADVANCE se asoció con reducción de terapias totales (RTIa=0,77; IC95%, 0,69-0,86) y choques inapropiados (RTIa=0,66; IC95%, 0,52-0,85). Conclusiones La adopción de la programación ADVANCE es poco amplia y puede mejorarse mediante una adecuada selección de los parámetros nominales. Emplearla se asocia con una reducción de las terapias del DAI. (AU)


Introduction and objectives The ADVANCE III trial showed that a delayed-detection strategy reduces implantable cardioverter-defibrillator (ICD) therapies. Here, we describe the adherence to and predictors of ADVANCE adoption and compare ICD therapy rates between patients with and without ADVANCE programming. Methods This observational retrospective study analyzed patients implanted with Medtronic ICDs included from 2005 to 2016 in a Spanish national multicenter registry (UMBRELLA database; ClinicalTrials.gov, NCT01561144). Changes in ADVANCE programming adoption were described in relation to a) publication of the ADVANCE trial, b) implementation of an “ADVANCE awareness” campaign, and c) publication of an expert consensus statement. Multivariate logistic regression identified predictors of adoption. Therapy incidence rates were compared between groups by estimating the adjusted incidence rate ratio (aIRR) using negative binomial regression. Results A total of 3528 patients were included. An ADVANCE strategy was used in 20% overall and in 44% at the end of the study. ADVANCE III adoption increased after trial publication, with less growth after an “ADVANCE awareness” campaign and after expert consensus statement publication. Predictors of ADVANCE adoption were as follows: ICD device with a nominal number of intervals to detect 30/40 (aOR, 4.4; 95%CI, 3.5-5.4), implantation by an electrophysiologist (aOR, 1.7; 95%CI, 1.4-2.2), and secondary prevention (aOR, 3.2; 95%CI, 2.6-3.9). Dual-chamber ICDs (aOR, 0.6; 95%CI, 0.5-0.8) and cardiac resynchronization-defibrillators (aOR, 0.5; 95%CI, 0.4-0.7) were associated with lower adoption. ADVANCE programming was associated with reduced total therapy burden (aIRR, 0.77; 95%CI, 0.69-0.86) and fewer inappropriate shocks (aIRR, 0.66; 95%CI, 0.52-0.85). Conclusions ADVANCE adoption remains modest and can be improved through evidence-driven selection of nominal ICD settings. ... (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Desfibriladores Implantáveis , Medicina de Precisão , Estudos Retrospectivos , Epidemiologia Descritiva
12.
J Cardiovasc Electrophysiol ; 32(6): 1584-1593, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33772926

RESUMO

BACKGROUND: The assessment of noninvasive markers of left atrial (LA) low-voltage substrate (LVS) enables the identification of atrial fibrillation (AF) patients at risk for arrhythmia recurrence after pulmonary vein isolation (PVI). METHODS: In this prospective multicenter study, 292 consecutive AF patients (72% male, 62 ± 11 years, 65% persistent AF) underwent high-density LA voltage mapping in sinus rhythm. LA-LVS (<0.5 mV) was considered as significant at 2 cm2  or above. Preprocedural clinical electrocardiogram and echocardiographic data were assessed to identify predictors of LA-LVS. The role of the identified LA-LVS markers in predicting 1-year arrhythmia freedom after PVI was assessed in 245 patients. RESULTS: Significant LA-LVS was identified in 123 (42%) patients. The amplified sinus P-wave duration (APWD) best predicted LA-LVS, with a 148-ms value providing the best-balanced sensitivity (0.81) and specificity (0.88). An APWD over 160 ms was associated with LA-LVS in 96% of patients, whereas an APWD under 145 ms in 15%. Remaining gray zones improved their accuracy by introduction of systolic pulmonary artery pressure (sPAP) of 35 mmHg or above, age, and sex. According to COX regression, the risk of arrhythmia recurrence 12 months following PVI was twofold and threefold higher in patients with APWD 145-160 and over 160 ms, compared to APWD under 145 ms. Integration of pulmonary hypertension further improved the outcome prediction in the intermediate APWD group: Patients with APWD 145-160 ms and normal sPAP had similar outcome than patients with APWD under 145 ms (hazard ratio [HR] 1.62, p = .14), whereas high sPAP implied worse outcome (HR 2.56, p < .001). CONCLUSIONS: The APWD identifies LA-LVS and risk for arrhythmia recurrence after PVI. Our prediction model becomes optimized by means of integration of the pulmonary artery pressure.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ecocardiografia , Eletrocardiografia , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
J Arrhythm ; 37(1): 259-260, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33664915

RESUMO

We describe through a clinical case some of the challenges we can face when remotely monitoring a patient with two devices. The case describes a patient with two leadless pacemaker in which data transmission by remote monitoring has been achieved.

14.
JACC Case Rep ; 3(18): 1918-1923, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34984353

RESUMO

Recurrence of atrial fibrillation (AF) despite successful isolation of the pulmonary veins (PVs) represents a great challenge. We present a patient with recurrent episodes of paroxysmal AF despite PV isolation in which a non-PV trigger was identified in the inferior vena cava. (Level of Difficulty: Intermediate.).

15.
JACC Clin Electrophysiol ; 7(6): 705-715, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33358670

RESUMO

OBJECTIVES: The study goal was to examine whether there are sex-related differences in the incidence of ventricular arrhythmias and mortality in CRT-defibrillator (CRT-D) recipients. BACKGROUND: Few studies have evaluated sex-related benefits of cardiac resynchronization therapy (CRT). Moreover, data on sex-related differences in the occurrence of ventricular tachyarrhythmias in this population are limited. METHODS: A multicenter retrospective study was conducted in 460 patients (355 male subjects and 105 female subjects) from the UMBRELLA (Incidence of Arrhythmia in Spanish Population With a Medtronic Implantable Cardiac Defibrillator Implant) national registry. Patients were followed up through remote monitoring after the first implantation of a CRT-D during a median follow-up of 2.2 ± 1.0 years. Sex differences were analyzed in terms of ventricular arrhythmia-treated incidence and death during the follow-up period, with a particular focus on primary prevention patients. RESULTS: Baseline New York Heart Association functional class was worse in women compared with that in men (67.0% of women in New York Heart Association functional class III vs. 49.7% of men; p = 0.003), whereas women had less ischemic cardiac disease (20.8% vs. 41.7%; p < 0.001). Female sex was an independent predictor of ventricular arrhythmias (hazard ratio: 0.40; 95% confidence interval: 0.19 to 0.86; p = 0.020), as well as left ventricular ejection fraction and nonischemic cardiomyopathy. Mortality in women was one-half that of men, although events were scarce and without significant differences (2.9% vs. 5.6%; p = 0.25). CONCLUSIONS: Women with left bundle branch block and implanted CRT have a lower rate of ventricular tachyarrhythmias than men. All-cause mortality in patients is, at least, similar between female and male subjects.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Arritmias Cardíacas , Feminino , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
16.
J Am Heart Assoc ; 10(1): e018108, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33356406

RESUMO

Background Large-scale studies describing modern populations using an implantable cardioverter-defibrillator (ICD) are lacking. We aimed to analyze the incidence of arrhythmia, device interventions, and mortality in a broad spectrum of real-world ICD patients with different heart disorders. Methods and Results The UMBRELLA study is a prospective, multicenter, nationwide study of contemporary patients using an ICD followed up by remote monitoring, with a blinded review of arrhythmic episodes. From November 2005 to November 2017, 4296 patients were followed up. After 46.6±27.3 months, 16 067 episodes of sustained ventricular arrhythmia occurred in 1344 patients (31.3%). Appropriate ICD therapy occurred in 27.3% of study population. Patients with ischemic cardiomyopathy (hazard ratio [HR], 1.51; 95% CI, 1.29-1.78), dilated cardiomyopathy (HR, 1.28; 95% CI, 1.07-1.53), and valvular heart disease (HR, 1.94; 95% CI, 1.43-2.62) exhibited a higher risk of appropriate ICD therapies, whereas patients with hypertrophic cardiomyopathy (HR, 0.72; 95% CI, 0.54-0.96) and Brugada syndrome (HR, 0.25; 95% CI, 0.14-0.45) showed a lower risk. All-cause death was 13.4% at follow-up. Ischemic cardiomyopathy (HR, 3.09; 95% CI, 2.58-5.90), dilated cardiomyopathy (HR, 3.33; 95% CI, 2.18-5.10), and valvular heart disease (HR, 3.97; 95% CI, 2.25-6.99) had the worst prognoses. Delayed high-rate detection was enabled in 39.7% of patients, and single-zone programming occurred in 52.6% of primary prevention patients. Both parameters correlated with lower risk of first appropriate ICD therapy, with no excess risk of mortality. The rate of inappropriate shocks at follow-up was low (6%) and did not differ among type of ICD but was lower in SmartShock-capable devices. Conclusions Irrespective of the cause, contemporary ICD patients with heart failure-related disorders had a similar risk of ICD life-saving interventions and death. Current ICD programming recommendations still need to be implemented. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NTC01561144.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Taquicardia Ventricular , Estudos de Coortes , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/classificação , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Cardioversão Elétrica/estatística & dados numéricos , Análise de Falha de Equipamento , Feminino , Cardiopatias/classificação , Cardiopatias/complicações , Cardiopatias/mortalidade , Cardiopatias/terapia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Determinação de Necessidades de Cuidados de Saúde , Serviços Preventivos de Saúde/métodos , Serviços Preventivos de Saúde/estatística & dados numéricos , Medição de Risco , Espanha/epidemiologia , Análise de Sobrevida , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia
17.
Rev Esp Cardiol (Engl Ed) ; 74(4): 296-302, 2021 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32773348

RESUMO

INTRODUCTION AND OBJECTIVES: The ADVANCE III trial showed that a delayed-detection strategy reduces implantable cardioverter-defibrillator (ICD) therapies. Here, we describe the adherence to and predictors of ADVANCE adoption and compare ICD therapy rates between patients with and without ADVANCE programming. METHODS: This observational retrospective study analyzed patients implanted with Medtronic ICDs included from 2005 to 2016 in a Spanish national multicenter registry (UMBRELLA database; ClinicalTrials.gov, NCT01561144). Changes in ADVANCE programming adoption were described in relation to a) publication of the ADVANCE trial, b) implementation of an "ADVANCE awareness" campaign, and c) publication of an expert consensus statement. Multivariate logistic regression identified predictors of adoption. Therapy incidence rates were compared between groups by estimating the adjusted incidence rate ratio (aIRR) using negative binomial regression. RESULTS: A total of 3528 patients were included. An ADVANCE strategy was used in 20% overall and in 44% at the end of the study. ADVANCE III adoption increased after trial publication, with less growth after an "ADVANCE awareness" campaign and after expert consensus statement publication. Predictors of ADVANCE adoption were as follows: ICD device with a nominal number of intervals to detect 30/40 (aOR, 4.4; 95%CI, 3.5-5.4), implantation by an electrophysiologist (aOR, 1.7; 95%CI, 1.4-2.2), and secondary prevention (aOR, 3.2; 95%CI, 2.6-3.9). Dual-chamber ICDs (aOR, 0.6; 95%CI, 0.5-0.8) and cardiac resynchronization-defibrillators (aOR, 0.5; 95%CI, 0.4-0.7) were associated with lower adoption. ADVANCE programming was associated with reduced total therapy burden (aIRR, 0.77; 95%CI, 0.69-0.86) and fewer inappropriate shocks (aIRR, 0.66; 95%CI, 0.52-0.85). CONCLUSIONS: ADVANCE adoption remains modest and can be improved through evidence-driven selection of nominal ICD settings. ADVANCE programming is associated with reduced therapy rates in real-world ICD recipients.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Cardioversão Elétrica , Humanos , Incidência , Estudos Retrospectivos
18.
CJC Open ; 2(5): 354-359, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32995720

RESUMO

BACKGROUND: The number of implantable cardioverter defibrillator (ICD) infections is increasing due to an increased number of ICD implants, higher-risk patients, and more frequent replacement procedures, which carry a higher risk of infection. Reducing the morbidity, mortality, and cost of ICD-related infections requires an understanding of the current rate of this complication and its predictors. METHODS: The Shock Implant Evaluation Trial (SIMPLE) trial randomized 2500 ICD recipients to defibrillation testing or not. Over an average of 3.1 years, patients were seen every 6 months and examined for evidence of ICD infection, which was defined as requiring device removal and/or intravenous antibiotics. RESULTS: Within 24 months, 21 patients (0.8%) developed infection. Fourteen patients (67%) with infection presented within 30 days, 20 patients by 12 months, and only 1 patient beyond 12 months. Univariate analysis demonstrated that patients with primary electrical disorders (3 patients, P = 0.009) and those with a secondary prevention indication (13 patients, P = 0.0009) were more likely to develop infection. Among the 2.2% of patients who developed an ICD wound hematoma, 10.4% developed an infection. Among the 8.3% of patients requiring an ICD reintervention, 1.9% developed an infection. CONCLUSIONS: This cohort of ICD recipients at high-volume centres have a low risk of device-related infection. However; strategies to reduce wound hematoma and the need for ICD reintervention could further reduce the rate of infection.


CONTEXTE: L'incidence des cas d'infection du défibrillateur cardioverteur implantable (DCI) augmente en raison du nombre accru d'implantations, de l'emploi de ces dispositifs chez des patients exposés à un risque très élevé et de l'augmentation de la fréquence des interventions de remplacement, qui sont associées à un plus grand risque d'infections. Pour parvenir à réduire la morbidité, la mortalité et les coûts associés aux infections liées à un DCI, il faut connaître la fréquence de cette complication et les facteurs qui permettent de la prédire. MÉTHODOLOGIE: Lors de l'essai S hock Impl ant E valuation Trial (SIMPLE), 2 500 patients ayant reçu un DCI ont été répartis aléatoirement en deux groupes, l'un subissant des tests de défibrillation et l'autre, non. Sur une période de 3,1 ans en moyenne, les patients ont été vus en consultation tous les 6 mois et examinés à la recherche de signes d'infection du DCI, définie comme étant une infection exigeant le retrait du dispositif et/ou l'administration d'antibiotiques par voie intraveineuse. RÉSULTATS: Au total, 21 patients (0,8 %) ont présenté une infection dans les 24 mois suivant l'implantation. Quatorze patients (67 %) ont présenté une infection dans les 30 jours suivant l'intervention; à 12 mois, 20 patients avaient présenté une infection. Un seul patient a présenté une infection plus de 12 mois après l'intervention. Les résultats d'une analyse univariée ont démontré qu'une infection était plus probable chez les patients qui présentaient un trouble électrique primaire (3 patients, p = 0,009) et chez ceux qui avaient reçu un dispositif en prévention secondaire (13 patients, p = 0,0009). Parmi les patients qui présentaient un hématome après l'implantation du DCI (2,2 %), 10,4 % ont présenté une infection. Parmi les patients qui ont eu besoin d'une nouvelle intervention relative au DCI (8,3 %), 1,9 % ont présenté une infection. CONCLUSIONS: Les patients de cette cohorte ayant reçu un DCI dans des établissements à haut volume étaient exposés à un faible risque d'infection du défibrillateur. Des stratégies visant à réduire les hématomes et la nécessité d'une nouvelle intervention sur les DCI pourraient toutefois contribuer à réduire encore plus la fréquence des infections.

19.
Rev. esp. cardiol. (Ed. impr.) ; 73(4): 307-312, abr. 2020. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-195611

RESUMO

INTRODUCCIÓN Y OBJETIVOS: El marcapasos transcatéter Micra presenta una alta efectividad y una tasa de complicaciones más baja que los marcapasos convencionales. Sin embargo, se desconoce su beneficio en la población más anciana (≥ 90 años). El objetivo de este estudio es evaluar la efectividad y la seguridad de Micra en pacientes de edad ≥ 90 años. MÉTODOS: Estudio observacional prospectivo con pacientes consecutivos mayores de 70 años a los que se implantó un marcapasos Micra, divididos en 2 grupos de edad: ≥ 90 y <90 años. RESULTADOS: El Micra se implantó en 129 pacientes, 41 tenían 90 o más años y 88, menos de 90. El implante fue exitoso en 40 pacientes (97,6%) de edad ≥ 90 años y en 87 (98,9%) menores de 90 (p = 0,58). Fueron necesarias 2 o menos reposiciones en el 97,5 y el 91,9% de los pacientes respectivamente (p = 0,32). Los tiempos de procedimiento (26,1±11,6 frente a 30,3±14,2min; p = 0,11) y de fluoroscopia (6,4±4,7 frente a 7,2±4,9min; p = 0,41) fueron similares en ambos grupos. Hubo 3 complicaciones mayores (2,3%), todas en el grupo menor de 90 años: 1 perforación cardiaca, 1 hematoma femoral y 1 seudoaneurisma femoral. Un total de 13 pacientes de edad ≥ 90 años (31,7%) y 16 de los menores de 90 (18,2%) murieron durante unos seguimientos medios de 230±233 y 394±285 días respectivamente. No hubo muertes relacionadas con el dispositivo. No se observaron infección, dislocación o migración de Micra. El rendimiento eléctrico fue óptimo en el seguimiento. CONCLUSIONES: El marcapasos sin cables Micra parece efectivo y seguro en pacientes mayores de 90 años. Podría considerarse una alternativa razonable a la estimulación transvenosa convencional en esta población


INTRODUCTION AND OBJECTIVES: The Micra transcatheter pacing system has shown high effectiveness and a lower complication rate than conventional transvenous pacemakers. However, the benefit of the device is unknown in the very old population (≥ 90 years). The aim of this study was to evaluate the safety and effectiveness of Micra in patients ≥ 90 years. METHODS: We present a prospective observational study with consecutive patients aged >70 years who underwent implantation of a Micra pacemaker system. Patients were divided into 2 groups: ≥ 90 and<90 years. RESULTS: The Micra system was implanted in 129 patients, of whom 41 were aged ≥ 90 years and 88<90 years. The device was successfully implanted in 40 (97.6%) patients ≥ 90 years and in 87 (98.9%) patients<90 years (P=.58). An adequate position was achieved with need for ≤ 2 repositions in 97.5% and 91.9% of patients, respectively (P=.32). Procedure time (26.1 ±11.6 vs 30.3 ±14.2minutes; P=.11) and fluoroscopy time (6.4 ±4.7 vs 7.2 ±4.9minutes; P=0.41) were similar in the 2 groups. There were 3 major complications (2.3%), all in the group aged<90 years: 1 cardiac perforation, 1 femoral hematoma, and 1 femoral pseudoaneurysm. Thirteen patients aged ≥ 90 years (31.7%) and 16 patients aged <90 years (18.2%) died during a mean follow-up of 230±233 days and 394±285 days, respectively. There were no device-related deaths. No infection, dislocation or migration of Micra were observed. The electrical performance was optimal at follow-up. CONCLUSIONS: The Micra leadless pacing system seems to be safe and effective in patients older than 90 years. It may be considered a reasonable alternative to conventional transvenous pacing in this population


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Bradicardia/terapia , Marca-Passo Artificial , Registros , Nó Sinoatrial/fisiologia , Bradicardia/fisiopatologia , Desenho de Equipamento , Estudos Prospectivos , Resultado do Tratamento
20.
Cardiovasc Drugs Ther ; 34(1): 89-94, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32096001

RESUMO

PURPOSE: The usefulness and mechanisms of antiarrhythmic drug (AAD) pre-treatment as a facilitator of the acute success of electrical cardioversion (ECV) in atrial fibrillation (AF) remain controversial. We sought to analyze the role of AAD treatment with this purpose, differentiating its possible utility either facilitating the restoration of sinus rhythm (SR) or reducing immediate AF recurrences (IAFR). METHODS: We analyzed 2962 consecutive patients with persistent AF undergoing ECV prospectively included in 3 national registries. The acute success of ECV was indicated by the reversion to SR without presenting an IAFR (< 2 h). RESULTS: A total of 1410 patients (48%) received AAD treatment prior to ECV (80% amiodarone, 15% class Ic AAD, 2% other AAD). The rate of restoration of SR was similar between the patients treated with amiodarone (92%), class Ic AAD (91%) and who did not receive AAD pre-treatment (91%) (p = 0.92). However, those treated with amiodarone had fewer IAFR than those in the other two groups (amiodarone 3% vs class Ic 7% vs without treatment 6%; p = 0.002), so the ECV success rate was higher in the amiodarone group than in the other groups (amiodarone 89% vs Ic 84% vs without treatment 86%; p = 0.04). After adjusting for multiple variables, amiodarone remained as an independent predictor of a lower occurrence of IAFR (OR = 0.57; p = 0.01) and of a successful ECV (OR 1.37; p = 0.01). CONCLUSIONS: For patients with persistent AF undergoing ECV, AAD has a neutral effect on the restoration of SR but amiodarone increases its effectiveness due to a lower incidence of IAFR.


Assuntos
Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Cardioversão Elétrica , Frequência Cardíaca/efeitos dos fármacos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Espanha , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...